The Relation Between Cardiac Output and Cerebral Blood Flow in ME/CFS Patients with a POTS Response During a Tilt Test

Abstract:

Background/Objectives: Orthostatic intolerance is prevalent in patients with myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) and is caused by an abnormal reduction in cerebral blood flow (CBF). In healthy controls (HCs), CBF is regulated complexly, and cardiac output (CO) is an important determinant of CBF. A review in HC showed that a 30% reduction in CO results in a 10% reduction in CBF. In contrast, we showed in ME/CFS patients with a normal HR (HR) and blood pressure response during a tilt test that CO and CBF decreased to a similar extent. The relation between CO and CBF in ME/CFS patients with postural orthostatic tachycardia syndrome (POTS) is unknown.

Therefore, the aim of this study is to assess the relation between CBF and CO, in ME/CFS patients with POTS. The methods used in this retrospective study analyze this relation in a large group of patients. We also analyzed the influence of clinical data. A total of 260 ME/CFS patients with POTS underwent tilt testing with measurements of HR, BP, CBF, CO, and end-tidal PCO2. We measured CBF using extracranial Doppler flow velocity and vessel diameters obtained with a General Electric echo system, and suprasternal aortic flow velocities were measured using the same device. We recorded end-tidal PCO2 using a Nonin Lifesense device.

Results: End-tilt HR and the HR increase were significantly higher in the patients with a %CO reduction ≥ -15% than in the other group. End-tilt CO was higher and the %CO reduction was lower in patients with %CO reduction ≥ -15% than in the other group. CBF data (supine, end-tilt and the %CBF reduction) were not different between the two patient groups. The use of HR increases and %SV reductions were not as discriminative as the %CO reduction.

Conclusions: In ME/CFS patients with POTS during tilt testing with measurements of both the CO and the CBF, two different patterns were observed: (1) appr. two-thirds of patients had an almost 1:1 relation between the %CBF reduction and the %CO reduction. (2) Appr. one-third of patients showed a limited reduction in CO together with a substantial increase in HR. In these patients, there was no relation between the CO and CBF reduction. These data suggest the presence of a hyperadrenergic response.

Source: van Campen CLMC, Visser FC. The Relation Between Cardiac Output and Cerebral Blood Flow in ME/CFS Patients with a POTS Response During a Tilt Test. J Clin Med. 2025 May 22;14(11):3648. doi: 10.3390/jcm14113648. PMID: 40507411. https://www.mdpi.com/2077-0383/14/11/3648 (Full text)

Two Different Hemodynamic Responses in ME/CFS Patients with Postural Orthostatic Tachycardia Syndrome During Head-Up Tilt Testing

Abstract:

Introduction: While the diagnosis of postural orthostatic tachycardia syndrome (POTS) is based on heart rate (HR) and blood pressure (BP) criteria, the pathophysiology of POTS is not fully understood as multiple pathophysiological mechanisms have been recognized. Also, cardiac function, being dependent on preload, afterload, contractility, and HR, has not been properly studied. Preload and contractility changes can be inferred from stroke volume index (SVI) changes during a tilt test. Afterload plays a minor role in POTS as a normal BP response is a prerequisite for POTS. Therefore, we analyzed the HR-SVI relation during a tilt test in myalgic encephalomyelitis (ME/CFS) patients with POTS and compared the data with ME/CFS patients with a normal HR-BP response and with that of healthy controls (HC).

Material and Methods: In ME/CFS patients with either POTS (n = 233) or a normal HR-BP response (n = 507) and healthy controls (n = 48), we measured SVI (by suprasternal echo), HR, and BP during the tilt.

Results: In all ME/CFS patients, the decrease in SVI was larger compared to HC. In patients with a normal HR-BP response and in POTS patients with a HR increase between 30-39 bpm, there was an inverse relationship between the HR increase and SVI decrease during the tilt, compatible with increased venous pooling. In POTS patients with a HR increase ≥40 bpm, this inverse relation was lost, and SVI changes were significantly less compared to POTS patients with a HR increase between 30-39 bpm, suggestive of a hyperadrenergic response.

Conclusions: In ME/CFS patients with POTS, two different hemodynamic profiles can be observed: in patients with a limited HR increase, mainly increased venous pooling is observed, while in patients with a large (≥ 40 bpm) HR increase the data are suggestive of a hyperadrenergic response. These two different profiles may have different therapeutic implications.

Source: van Campen CLMC, Rowe PC, Visser FC. Two Different Hemodynamic Responses in ME/CFS Patients with Postural Orthostatic Tachycardia Syndrome During Head-Up Tilt Testing. J Clin Med. 2024 Dec 18;13(24):7726. doi: 10.3390/jcm13247726. PMID: 39768649. https://www.mdpi.com/2077-0383/13/24/7726 (Full text)