Reduced exercise capacity, chronotropic incompetence, and early systemic inflammation in cardiopulmonary phenotype Long COVID

Abstract:

Background: Mechanisms underlying persistent cardiopulmonary symptoms following SARS-CoV-2 infection (post-acute sequelae of COVID-19 “PASC” or “Long COVID”) remain unclear. This study sought to elucidate mechanisms of cardiopulmonary symptoms and reduced exercise capacity.

Methods: We conducted cardiopulmonary exercise testing (CPET), cardiac magnetic resonance imaging (CMR) and ambulatory rhythm monitoring among adults > 1 year after confirmed SARS-CoV-2 infection in a post-COVID cohort, compared those with or without symptoms, and correlated findings with previously measured biomarkers.

Results: Sixty participants (median age 53, 42% female, 87% non-hospitalized) were studied at median 17.6 months following SARS-CoV-2 infection. On CPET, 18/37 (49%) with symptoms had reduced exercise capacity (<85% predicted) compared to 3/19 (16%) without symptoms (p = 0.02). Adjusted peak VO2 was 5.2 ml/kg/min lower (95%CI 2.1-8.3; p = 0.001) or 16.9% lower percent predicted (95%CI 4.3-29.6; p = 0.02) among those with symptoms. Chronotropic incompetence was common. Inflammatory markers and antibody levels early in PASC were negatively correlated with peak VO2 more than 1 year later. Late-gadolinium enhancement on CMR and arrhythmias were absent.

Conclusions: Cardiopulmonary symptoms >1 year following COVID-19 were associated with reduced exercise capacity, which was associated with elevated inflammatory markers early in PASC. Chronotropic incompetence may explain exercise intolerance among some with cardiopulmonary Long COVID.

Source: Durstenfeld MS, Peluso MJ, Kaveti P, Hill C, Li D, Sander E, Swaminathan S, Arechiga VM, Lu S, Goldberg SA, Hoh R, Chenna A, Yee BC, Winslow JW, Petropoulos CJ, Kelly JD, Glidden DV, Henrich TJ, Martin JN, Lee YJ, Aras MA, Long CS, Grandis DJ, Deeks SG, Hsue PY. Reduced exercise capacity, chronotropic incompetence, and early systemic inflammation in cardiopulmonary phenotype Long COVID. J Infect Dis. 2023 May 11:jiad131. doi: 10.1093/infdis/jiad131. Epub ahead of print. PMID: 37166076. https://academic.oup.com/jid/advance-article/doi/10.1093/infdis/jiad131/7159960 (Full text available as PDF file)

Orthostatic chronotropic incompetence in patients with myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS)

Highlights:

  • Adults with ME/CFS experience a 3-fold greater reduction in cerebral blood flow during end-tilt tilt compared to healthy controls, confirming orthostatic intolerance.
  • During tilt testing we found that in 134/362 (37%) patients with ME/CFS without POTS or hypotension, the heart rate increase was below the lower limit of the 95% prediction interval of the heart rate increase of controls, indicative of orthostatic chronotropic incompetence.
  • These novel findings represent the first description of orthostatic chronotropic incompetence during tilt testing, confirming another abnormality in the circulatory response to upright posture in ME/CFS.

Abstract:

Background: Orthostatic intolerance (OI) is a core diagnostic criterion in myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). The majority of ME/CFS patients have no evidence of hypotension or postural orthostatic tachycardia syndrome (POTS) during head-up tilt, but do show a significantly larger reduction in stroke volume index (SVI) when upright compared to controls. Theoretically a reduction in SVI should be accompanied by a compensatory increase in heart rate (HR). When there is an incomplete compensatory increase in HR, this is considered chronotropic incompetence.

This study explored the relationship between HR and SVI to determine whether chronotropic incompetence was present during tilt testing in ME/CFS patients.

Methods: From a database of individuals who had undergone tilt testing with Doppler measurements for SVI both supine and end-tilt, we selected ME/CFS patients and healthy controls (HC) who had no evidence of POTS or hypotension during the test.

To determine the relation between the HR increase and SVI decrease during the tilt test in patients, we calculated the 95% prediction intervals of this relation in HC. Chronotropic incompetence in patients was defined as a HR increase below the lower limit of the 95th % prediction interval of the HR increase in HC.

Results: We compared 362 ME/CFS patients with 52 HC. At end-tilt, tilt lasting for 15 (4) min, ME/CFS patients had a significantly lower SVI (22 (4) vs. 27 (4) ml/m2; p<0.0001) and a higher HR (87 (11) vs. 78 (15) bpm; p<0.0001) compared to HC. There was a similar relationship between HR and SVI between ME/CFS patients and HC in the supine position.

During tilt ME/CFS patients had a lower HR for a given SVI; 37% had an inadequate HR increase. Chronotropic incompetence was more common in more severely affected ME/CFS patients.

Conclusion: These novel findings represent the first description of orthostatic chronotropic incompetence during tilt testing in ME/CFS patients.

Source: C. (Linda) M.C. van Campen, Freek W.A. Verheugt, Peter C. Rowe, Frans C. Visser. Orthostatic chronotropic incompetence in patients with myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). IBRO Neuroscience Reports [In Press, Journal Pre-proof]  Available online 2 May 2023 https://www.sciencedirect.com/science/article/pii/S2667242123000374 (Full text)

Orthostatic Intolerance and Chronotropic Incompetence in Patients With Myalgic Encephalomyelitis or Chronic Fatigue Syndrome

Abstract:

Background: Orthostatic intolerance markedly affects the day-to-day activities of patients with myalgic encephalomyelitis (ME) or chronic fatigue syndrome. Chronotropic incompetence (CI), defined as an impaired chronotropic response or reduced increases in heart rate during exercise and resulting in lower exercise capacity, may also be observed during orthostasis in patients with ME.

Methods and Results: In this study, the recordings of 101 adult patients with ME (36 men, 65 women; mean [±SD] age 37±12 years) who underwent conventional active 10-min standing tests at least 3 times to determine the presence of CI were analyzed. Recordings were selected for 13 patients who experienced tests both with and without exhibiting postural orthostatic tachycardia syndrome (POTS; an increase in heart rate of ≥30 beats/min or an actual heart rate of ≥120 beats/min) while also both successfully completing and failing to complete 10-min standing on different occasions. Subjects in whom failure without POTS was observed in any test(s) while success was associated with POTS on other occasions were considered positive for CI during orthostasis. Of the 13 patients, 12 (92%) were CI positive, 5 (38%) of whom exclusively failed the tests without experiencing POTS.

Conclusions: Some patients with ME were CI positive during standing tests, suggesting impaired sympathetic activation. The presence of POTS appears to be essential for maintaining orthostasis in these patients.

Source: Kunihisa Miwa. Orthostatic Intolerance and Chronotropic Incompetence in Patients With Myalgic Encephalomyelitis or Chronic Fatigue Syndrome. Circulation Reports, Article ID CR-22-0114. https://www.jstage.jst.go.jp/article/circrep/advpub/0/advpub_CR-22-0114/_html/-char/en (Full text)